5-54
Liquefier Alignment
This aligns the Liquefier Tubes with the filament path.
1.
Right (Model) side:
A.
Move the Toggle Bar to the full Right position.
B.
Make sure the right side Heater Block Mount and Clamp
screws are loose.
C.
Make sure that the Liquefier Alignment Rod is straight. Roll the Rod along a flat
surface to check for bends. Straighten as necessary.
D.
Insert the Liquefier Alignment Rod from the bottom of the right side heater block
- small end first.
E.
Push the Alignment Rod up into the Main Pivot Block.
F.
Position the Liquefier Alignment Rod so that the stepped portion is flush with the
top of the Heater Block.
G.
Tighten the Heater Block Clamp screws.
H.
Move the Toggle Bar to the full Left position.
I.
Tighten the lower Heater Block Mount screw until it is snug.
J.
Tighten the upper Heater Block Mount screw until it is snug.
K.
Tighten the lower and upper Heater Block Mount screws to final torque.
L.
Move the Toggle Bar to the right until the Drive Wheel no longer contacts the
Liquefier Alignment Rod.
M.
Loosen the Heater Block Clamp screws and remove the Liquefier Alignment Rod.
2.
Left (Support) side:
A.
Repeat step 1 above - except reverse the Toggle Bar positions.
Caution:
Use care when moving the Toggle Bar. Forcing the bar, or applying too
much pressure, will damage the Liquefier Alignment Rod and cause a
misalignment of the Liquefier Tubes with the filament path.
Note:
Make sure that the Heater Block does not move while tightening the mount
screws.
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...