uPrint/uPrint SE Service Manual
5-41
Get/Send Calibration Files
The .cal file contains the calibration values for the system. If the hard drive is replaced the
.cal file must be downloaded for the system to function properly.
The “Get” button copies the .cal file from the system hard drive to the system calibration CD.
The “Send” button copies the .cal file from the system calibration CD to the system hard
drive. The system CD is located in the electronics bay of the system.
Parts and Tools Required
• MaracaEX
• Workstation
• System calibration CD
• Blank CD (if using the “get” command)
Get/Send calibration files
“Send” .cal file – from the system calibration CD to the printer
1.
Remove the system calibration CD from the electronics bay and insert into the
workstation CD drive.
2.
Install and open MaracaEX. Ensure that communications has been established with the
system.
3.
Select “Send” and browse to the CD drive.
4.
Select the xxx.cal (where xxx equals printer name) from the CD by double clicking on the
file name.
5.
To complete sending the file, click on the green check mark. This will write the file to the
system hard drive.
6.
Cycle power on the printer.
7.
Replace the CD into the electronics bay.
Note:
Do not use spaces in the .cal file name.
Note:
Once the system is upgraded and anytime calibration changes are made
the .cal file should be written (“Get”) from the system hard drive to a new system
CD. The new CD should then be stored in the electronics bay.
Note:
This procedure would typically be used after installation of a new hard
drive.
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...