2-14
Figure 2-6: Test points and LEDs detail
Component
Test Pt Description
UPS
TP29
Power fail signal from external UPS
+5V REF
TP24
Head T/C service reference
Door Switch
TP15
State of the door (open or closed)
On/Off Switch
TP14
State of power down switch
Power Enable
TP8
Enables power to circuitry (normally high)
Model Toggle
TP17
Toggle travel complete
Chamber Thermocouple
TP28
Voltage corresponds to chamber temperature (10 mV=° C)
Support Thermocouple
TP20
Voltage corresponds to support temperature
(10 mV=° C)
Model Thermocouple
TP22
Voltage corresponds to model temperature
(10 mV=° C)
HD Thermostat
TP25
Chamber and head thermostat (snap switches)
(+5 VDC if both switches closed)
Normal = tp17 lo, tp19 hi
ch thermostat fault=tp17 lo, tp19 lo.
Head TC Alarm
TP26
High if head T/C not plugged in or open
Support Toggle
TP16
Not used
Chamber TC Alarm
TP27
High if chamber T/C not plugged in or open
X EOT
TP18
X end of travel sensor (5 VDC), switches are wired normally closed (NC)
X Home
TP19
X home sensor (5 VDC), switches are wired normally closed (NC)
Y EOT
TP12
Y end of travel sensor (5 VDC), switches are wired normally closed (NC)
Y Home
TP13
Y home sensor (5 VDC), switches are wired normally closed (NC)
Z EOT
TP10
Z end of travel sensor (5 VDC), switches are wired normally closed (NC)
Z Home
TP9
Z home sensor (5 VDC), switches are wired normally closed (NC)
Z Substrate
TP23
Z substrate sensor (5 VDC)
HD Type A
TP21
Not used
HD Type B
TP30
Not used
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...