5-36
33.
Add the lengths derived from steps
and
(A-E and E-I) and then subtract the width
of circle E derived from step
. Record this total as “Left Front”
34.
Open MaracaEX and select the Current Modeler from the pull down menu.
35.
Open the
Open Gantry Calibration
Dialog box in MaracaEX.
36.
In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT, REAR, LEFT
FRONT and LEFT REAR. Enter the measurements in the appropriate box.
37.
Once the values have been entered, click on the green check mark.
38.
Toggle the system power switch to accept the new values.
39.
Run a test part to verify system is operating correctly.
Part Measurement Equations
Use the equation table below to record part measurements. Refer to these equations when
entering values in MaracaEX.
Front: _ ______ - ____ = ________
(A + B) + (B + C) - B
Right: _ ______ - ____ = ________
(C + F) + (F +I) - F
Left: _ ______ - ____ = ________
(A + D) + (D + G) - D
Rear: _ ______ - ____ = ________
(G + H) + (H + I) - H
Left Rear: _ ______ - ____ = ________
(C + E) + (E + G) - E
Left Front: _ ______ - ____ = _______
(A + E) + (E + I) - E
Figure 5-352: Part based calibration measurement locations
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...