Figure 4-274: XY Leveling bracket location
32.
Move the dial indicator to the back left corner and zero the dial indicator.
33.
Move the dial indicator to the front left corner and write down the value.
34.
Move the dial indicator to the front right corner and write down the value.
35.
Move the dial indicator to the back right corner and write down the value.
36.
Enter the values that are written down into the XY level worksheet. Use the 8x6
worksheet for uPrint and uPrint SE, see
Use the 8x8 worksheet for uPrint
Plus and uPrint SE Plus, see