System Specifications
Disposing of the Filters
Page 12
© Copyright 2020 Stratasys. All rights reserved.
4. Insert the new filter into position.
5. Replace the cover, and fasten the clips.
Disposing of the Filters
The combined filter is manufactured from non-toxic materials. Filters are not re-usable. The
method of disposal of the used filters depends on the material deposited on them.
It is the customer's responsibility to verify that the disposal of filters complies with all local
and/or industrial regulations.
System Specifications
• Capacity: 75 m³/h (44CFM)
• Weight: 10.5 kg (23.1 lbs)
• Fan type: Centrifugal
• Power: 100 W
• Voltage: 100-230 VAC
• Frequency: 50/60 Hz
• Full Load Current: 2.0 A
• Noise Level: Below 57 dBA (at typical operating speed)
• Overvoltage category: II
• Maximum altitude: 2000 m (6561 ft.)
• Allowable voltage input: +/-10%
• Control cable: 22-48 VDC input, 20 mA
Dimensions
Do not activate the system without a filter.
Metric (mm) Imperial (inches)
Height
413
16.3
Depth
298
11.7
Width
283
11.1