Part Replacement Procedures
Replacing the Resin Ingress Tube
Page 66
© Copyright 2022 Stratasys. All rights reserved.
Part Replacement Procedures
Replacing the Resin Ingress Tube
Required Tools
Nitrile gloves
Wire cutters
Nylon tube
Tube plugs
Two zip ties
4 mm hex driver
T10 Torx driver
Procedure
1. Open the printer door and remove the resin tray, if installed.
2. With the door open, power down and unplug the printer.
3. Using a T10 Torx driver, remove the two fasteners securing the access panel on the left
side of the printer.
4. Remove the interlocks from the back panel.
5. Using a 4mm hex wrench, loosen the five captive fasteners securing the back panel door.
6. Open the back panel door and, if required, brace the door open for easy access.
WARNING:
Do not pull the back panel all the way back. There is a cable attached to it from the
inside.