Stratasys J4100 User Guide
4 Operating and Maintaining the Printer
DOC-26000 Rev. C
4-87
Calibrating the Load Cells
Load cells are sensors that measure the weight of the material containers and
the waste container in the printer. It is important that you periodically check that
the weight measurements are accurate to prevent unnecessary waste of printing
materials or printer malfunctions.
To calibrate load cells:
1. Start the Load Cell Calibration wizard from the
Options
menu.
2. In the following screen, select one or more load cells that you want to
calibrate.
Figure 4-123 Load cell selection
3. Make sure that there are no containers on the load cells that you want to
calibrate, and click
Next
.
4. In the next wizard screen, observe the numbers and wait until the weight level
is relatively stable—two units above or below the average level shown.
Figure 4-124 Weight stabilization
5. Select the check box, and click
Next
.