DOC-03050 Rev. A
6–27
Eden350V User Guide
Improving
Print Quality
If
you
suspect
that
quality
is
poor,
perform
the
pattern
test
(see
on
If
the
results
are
poor,
use
the
following
procedure
to
improve
quality.
If the results of the last pattern test are poor:
1. From
the
Options
menu,
select
Purge Sequence
,
or
press
F4
.
2. In
the
confirmation
dialog
box,
click
Yes
.
The
heads
are
purged
of
Model
and
Support
material,
and
the
wiper
removes
excess
material
from
them.
3. Repeat
the
purge
sequence.
4. Perform
the
pattern
test.
If the results of the pattern test are still poor:
1. Manually
clean
the
heads
(see
2. Perform
the
purge
sequence.
3. Perform
the
pattern
test.
If the results of the pattern test are still poor:
1. Carefully
clean
the
heads
again,
making
sure
there
is
no
residue
left
on
them.
2. Perform
the
purge
sequence.
3. Perform
the
pattern
test.
If the results of the pattern test are still poor:
¾
Optimize
the
heads
and
replace
faulty
heads,
if
necessary
(see
page 37).