Stratasys 155-01200 Site Preparation Manual Download Page 1

Part No. 821465-0007_REV_A

Fortus

®

 380/450mc 

K5/K0 Series

SITE PREPARATION GUIDE

Summary of Contents for 155-01200

Page 1: ...Part No 821465 0007_REV_A Fortus 380 450mc K5 K0 Series SITE PREPARATION GUIDE...

Page 2: ...rt of this document may be photocopied reproduced or translated into another language without the prior written consent of Stratasys Inc All drawings and information herein are the property of Stratas...

Page 3: ...wer Consumption 4 ELECTRICAL REQUIREMENTS 4 AC Power Requirements 4 Optional UPS Connectivity 5 Optional AC Transformers 5 LAN REQUIREMENTS 7 RECEIVING THE PRINTER 7 INSPECT CRATE FOR DAMAGE 7 PREPARI...

Page 4: ...procedures for first aid and emergency assistance at the customer facility Use adequate lighting at the equipment Maintain the recommended range of temperature and humidity in equipment area Do not u...

Page 5: ...l User Interface 450MC HIGHLIGHTS Maximum build area of 16 x 14 x 16 inch 406 x 356 x 406 mm Material Canister Bays 2 model 2 support Touchscreen Graphical User Interface HOW TO USE THIS GUIDE This gu...

Page 6: ...ee Removal of Rear Panels and Cover on page 13 for instructions An absolute minimum printer height of 73 inches 185 42 cm can be achieved through the removal of several structural components by a qual...

Page 7: ...0 cm on each side Rear Clearance Minimum 12 inches 30 48 cm Front Clearance Minimum 36 inches 91 44 cm Overhead Clearance Minimum 24 inches 60 96 cm 24 inches 60 96 cm minimum for overhead clearance 3...

Page 8: ...the printer Heat output is material dependent due to the various temperatures maintained in the build chamber POWER CONSUMPTION Power consumption is material dependent due to the various temperatures...

Page 9: ...s female D Sub 9 pin this is NOT a serial communication port Only pins 7 and 9 of the connector are used with remaining pins having no internal connections When the circuit between pins 7 and 9 is ope...

Page 10: ...wires typically colored yellow red and orange must be moved to the appropriate tap position terminal block number shown on the connection diagram attached to the inside cover of the transformer 3 phas...

Page 11: ...r DHCP or Static IP configurations RECEIVING THE PRINTER INSPECT CRATE FOR DAMAGE Before opening the shipping crate inspect the crate for signs of exterior damage Report evidence of excessive damage t...

Page 12: ...ill assist your installation representative in determining the cause of damage Figure 5 2 Using a Phillips screwdriver remove the cover mount screws from the base of the crate Figure 5 Figure 5 Shippi...

Page 13: ...npacking the Printer cover removed 7 Remove the printer from the shipping base this can be done using a fork lift see Remove Printer from Shipping Base Fork Lift Instructions on page 10 or manually vi...

Page 14: ...y lower the printer until it rests on its casters 5 Inspect the printer s exterior for dents and scratches Immediately report any damage to Stratasys and the shipping company 6 Roll the printer into i...

Page 15: ...ure 9 Figure 8 Ramp Hardware viewed from side Warning Before removing the printer via the ramp ensure that you have enough manpower to remove the printer from the shipping base as the printer is heavy...

Page 16: ...the printer s exterior for dents and scratches Immediately report any damage to Stratasys and the shipping company 7 Roll the printer into its approximate operating location Caution Use care when cutt...

Page 17: ...t required proceed to Service Connections on page 16 To remove the rear service access panels 1 Using a 5 mm Allen wrench loosen but do not remove the 4 fasteners securing the upper rear panel see Fig...

Page 18: ...p clamp mounting screws 2 from the upper p clamps Figure 11 3 Using a 5 mm Allen wrench remove the p clamp mounting screws 2 from the lower p clamps Figure 11 Figure 11 Disconnect Fan Wiring P Clamps...

Page 19: ...r up and away from the printer to remove and set aside Figure 14 Figure 14 Rear Top Cover Removal Note Only remove the hinge screws from the crossbar which secure the top cover to the printer Do not r...

Page 20: ...e ground lug protective earth Figure 15 Line Connections Warning A licensed electrician must perform all AC electrical service connections to the printer Consult a licensed electrician to comply with...

Page 21: ...aterials and applications call 888 480 3548 or visit www stratasys com DOCUMENTATION FEEDBACK Customers resellers and Stratasys employees are encouraged to send comments about our documentation and tr...

Reviews: