508 Door Lock Control Assignment
This assignment is used to configure up to 10 door lock control relays. The contacts of these relays are
used to control electrical door locks. One door lock relay can be assigned to each of the eight door phone
control boxs (DDCB, Port -B) and/or one to each of the two BIOU PCBs (any one of the four control
relays).
Note
If a door lock is assigned to a DDCB, the second jack (Port B) will provide the door lock relay
contacts. This jack can not be used to connect an MDFB door phone.
F
IELD
D
ESCRIPTION
00 Door Lock Number
Enter the door lock control number to configure.
Possible values:1~3 CTX28, CIX40, 1~4 CIX100, 1~5 CIX670 Basic, 1~10 CIX670
and CIX1200 Expanded (default = no value)
01 Interface Type
Door lock control relay contacts are provided by the DDCB (Port - B) and BIOU
interface control relays.
Possible values:None (default), BIOU or DDCB
02 BIOU Relay Number
Assign BIOU control relay as a door lock relay. This relay activates when the door
lock button is pressed or a door lock access code is dialed.
Possible values:0~8 (default = 0) BIOU1 provides control relays 1~4; BIOU2
provides control relays 5~8.
Note
Assign BIOU control relay (1~8) as a door lock relay - this relay activates
when a door lock button is pressed or a door lock access code is dialed.
BIUO1 provides control relays 1 to 4. BIUO2 provides control relays 5 to 8.
The CIX100 ACTU and CIX200 built-in relays are programmed as relay 5.
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...