443581626885
1
Quick Start Guide
ViSion.net din rail
encloSure - Small
OVERVIEW
This document provides installation and operation instructions for the following product(s):
PRODUCT NAME
ORDER CODE
Vision.Net DIN Rail Enclosure - Small
53906-001
inStallation and Set uP
To prepare the Vision.Net DIN Rail Enclosure - Small for installation:
Step 1.
Place enclosure on a flat surface.
Step 2.
To remove cover, use a #2 Philips screwdriver to remove two screws from the bottom of the cover,
and loosen the top two screws. Slide cover upwards to disengage keyhole mounts.
Step 3.
Remove accessories from the enclosure.
Step 4.
Determine appropriate knockouts and mounting holes to use for your specific application. If ground-
ing the enclosure, note the desired orientation of the ground stud prior to removing knockouts.
Step 5.
To remove a knockout, position the tip of a flat head screwdriver against the stamped edge and
pressing down sharply and tapping the screwdriver with a hammer. Once the knockout is dislodged
use a pair of pliers to grab the knockout, twisting back and forth until the attachment points snap.
Repeat as needed.
mountinG
The enclosure must be mounted using at least four points of contact. If installed below grade to an exterior wall
take care to install a vapor barrier between enclosure and wall to avoid rusting of enclosure.
To surface mount the Vision.Net DIN Rail Enclosure - Small:
Step 1.
Prepare surface as needed for mounting of enclosure. Mark locations on surface for the four mount-
ing holes located on the rear of the enclosure.
Step 2.
Mount enclosure using 5/16” rounded head fasteners. If mounting to a hollow wall, concrete or block
use appropriate anchors where required.
To flush mount the Vision.Net DIN Rail Enclosure - Small:
Step 1.
Prepare surface as needed for mounting. Mark locations in wall cavity for the four mounting holes
located on the left and right side of the enclosure.
Step 2.
Mount enclosure using 1/4” rounded head fasteners or similar. If mounting to a hollow wall, concrete
or block use appropriate anchors where required.
VoltaGe Barrier inStallation
To install voltage barriers for the Vision.Net DIN Rail Enclosure - Small (if required):
Step 1.
Determine placement of voltage barriers. The enclosure includes two static horizontal barriers and an
adjustable vertical barrier that mounts on the DIN rail.
Step 2.
Install required vertical barriers by removing and reinstalling the corresponding #2 Phillips head
screws.
Step 3.
Install the vertical barrier to the desired DIN rail. Barrier can be adjusted after installation of DIN
devices and secured in place by tightening the #2 Phillips head screw. Do not over-tighten.
Step 4.
To protect wiring from abrasion, install edge grommet on barriers. Cut the required length of grom-
met and press into the notches of the barrier.