2
(not drawn to scale)
IN THE BOX
(not drawn to scale)
STFS PLUS SENSOR CANNISTERS
ONE ASSEMBLED PAIR FOR EACH 4-BURNERS
STFS PLUS SENSOR CANISTERS
WHAT’S IN THE BOX
Bottom View
Sensor Board Detail View
Side View
Top View
H
G
A
A
A
B
B
STFS PLUS S MECHANICAL INSTALLATION
(3)
(2)
1)
Must have 15-32” (38-81 cm) between surface of cooktop and mounting point in range hood. Clean and dry areas in range hood where both
magnets will attach.
2)
Position canisters in range hood at the midpoint between the center of front and back burners on each side.
3)
Raise canisters to the spot directly above in range hood.
4)
Place the enclosed decal where it can be seen in the ventilation hood.
If the magnet does not attach, go to www.STFS.com to order an alternative mounting kit.
(4)
(1)
A.
STFS Plus Sensor Canister
B.
Magnet
C.
Sensor Board
D.
Test / Reset Button
E.
Board Screws (3 per canister)
F.
Pull Tab
G.
Decal, 1 per pair
H.
Expiration Date (on Label)
E
C
D
C
F
A
F