32
T E C H N I C A L D ATA
6
WARNING
- This cooker must be earthed
G A S - R A N G E
Data badge
Lower part of the front frame
Appliance class
Class 1 - freestanding cooker
Electrical supply
220 - 240V ~ 50 Hz
Load
4135 - 4920 W
Max. heat input
∑
Qn 9.00 kW
Type of gas
This cooker can be used with Natural Gas and LPG.
Gas category
Natural gas II2H3+
Gas pressure settings
G20 Natural Gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Burner Aeration
Fixed
Ovens and Grill
Electric
Hob
Burners have burner heads and caps which are removable for cleaning.
Concealed electrodes to each burner.
Burner / Element
Nominal rate Qn (kW)
Injector size
G20/G30
G31
G20/G30
G31
Hob - small
1.0
0.9
77
50
Hob - medium
2.0
1.8
104
70
Hob - wok
4.0
3.6
152
100
Max. heat input
∑
Qn 9.00 kW
∑
Qn 8.10 kW
-
-