background image

 

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

 

Table 1. Heater specifications 
 

1.

 

GENERAL 

Stoveman

 product range includes various modifications of sauna heaters. You can choose between round and angular shaped 

stoves. The heater may have a door panel made of heat-resistant glass or metal (M). The heater can be heated directly from 
the hot room or have an extended fire chamber (LS) to be heated 
from another room.

  

Declaration of performance for the purchased 
sauna heater type is annexed to the manual. 

 

Choose  the  heater  with  suitable  heating  output  for  your  sauna 
room. Sauna room’s suitable cubage for this heater is given in the 
specifications. 
When  choosing  a  suitable  heater  it  is  important  to  know  that 
uninsulated  wall  and  ceiling  surfaces  (such  as  brick,  glass,  stone 
and concrete surfaces) increase the required output of the heater.  
Our sales assistant or a representative of our factory can assist you 
at  choosing  a  suitable  heater or you  can  use  a  special  application 
for  choosing  the  heater  on  our  website 

www.stoveman.ee

 

http://www.stoveman.ee/kerise-valimine/ 

 

1.1. Heater components 

 (See Fig. 1) 
 

1-

 

Heater stones (not included in the supply) 

2-

 

Steel mesh 

3-

 

Cleaning hatch 

4-

 

Flue gas outlet to be connected with chimney pipe 

5-

 

Heater casing 

6-

 

Fire chamber door 

7-

 

Glass panel door (optional metal door) 

8-

 

Ash drawer 

9-

 

Fire chamber extension for wall penetration (LS models) 

10- Fire grate 

 

 

 

 

 

 

 

 

 

Figure 1. Heater components

 

Type 

Stoveman 16 

Models 

16R;  16R-M;  16;  16-M;  16R-LS;  16R-M-LS; 
16-M-LS; 16-LS 

Heating output in the sauna room 

17 kW 

Sauna room cubage  

8-16 m³ 

Fuel 

Wood logs up to 40 cm in length 

Refuelling loads 

11,2 kg in three parts 

Minimum required draft  

12 Pa 

Required temperature class of chimney 

T600 

Inner diameter of a chimney pipe to be connected to the 
heater 

115 mm 

Safety distance to combustible materials: 

 sides 

ceiling 

back 
front (from the furnace door) 

 
500 mm 
1200 mm 
500 mm 
1000 mm 

Carbon dioxide emissions at 13% O

2

 content 

0.61% 

Total efficiency  

66% 

Flue gas temperature 

443 °C 

Weight without sauna stones  

70 kg

 /

 LS 82 kg; Heavy  92 kg

 /

 LS 107 kg   

Weight of sauna stones  

140 kg 

Diameter of sauna stones  

10–15 cm 

Minimum cross-section of ventilation openings 

7850 mm² 

Minimum cross-section of smoke flue 

10200 mm² 

Thickness of furnace walls and ceiling  

5 mm; Heavy-8mm  

Opening of the ash drawer after igniting the stove 

up to 10 mm 

Mass of generated flue gas 

14,7 g/s 

Summary of Contents for Stoveman 16

Page 1: ...nents See Fig 1 1 Heater stones not included in the supply 2 Steel mesh 3 Cleaning hatch 4 Flue gas outlet to be connected with chimney pipe 5 Heater casing 6 Fire chamber door 7 Glass panel door optional metal door 8 Ash drawer 9 Fire chamber extension for wall penetration LS models 10 Fire grate Figure 1 Heater components Type Stoveman 16 Models 16R 16R M 16 16 M 16R LS 16R M LS 16 M LS 16 LS He...

Page 2: ...stones and the outlets are located as far away from the heater as possible so that the core outlet is placed 50 100 mm higher from the floor and the opening required for adjusting comes from the same channel drawn out under the ceiling The grilles installed on the inlet s should not impede the necessary amount of air flow Mechanical forced ventilation fans may cause problems Forced ventilation sys...

Page 3: ...st be inspected by a person with relevant expertise 2 6 Installation of a heater with fire chamber expansion heated from another room See Fig 4 The heater must be installed into an opening of a concrete or brick wall The recommended dimensions of the opening are Height H 470 mm Width L 320 mm Thickness Depth P 200 mm If the floor in front of the fire chamber door is made of flammable material a fl...

Page 4: ...the standard load This is especially important in case of low draft due to poor weather conditions in which case the recommended initial load is 1 3 of the norm Table 1 using 3 5 cm diameter logs Place the ignition material on top of the firewood Starting the fire on the top part of the wood load produces lower emissions and combustion is of higher quality 5 Light the ignition material and close t...

Page 5: ...s of the heater are blocked Clean the smoke ducts of the heater The flue pipe is installed too deep into the chimney flue Install the flue pipe correctly Sauna does not heat up The sauna room is too big for the heater s heating output section 1 The sauna has uninsulatd wall surface Have the quality of construction inspected and bring the construction in compliance with the requirements Firewood is...

Page 6: ...5 ...

Page 7: ...6 Manufactured by AS Eesti Vanglatööstus Kalmistu tee 22 11216 TALLINN ESTONIA Tel 372 677 6700 Fax 372 677 6701 www stoweman ee ...

Reviews: