Minimum Hearth Extension Requirements
The hearth extension floor area must extend at least 20" (508 mm) in front of the hearth
(A)
and at least 8"
(20 cm) on each side of the door opening (
D
). The joint between the hearth extension and the fireplace
hearth needs to be made of non-combustible material such as sheet metal (not included).
CLEARANCES
A
20" (508 mm)
B
38" (965 mm)
C
8" (203 mm)