background image

Adjust the folds equally around the 
Valve Collar making certain that the 
Valve hangs straight down when the 
Balloon is held at the end. 
Bend the protruding end of the Bal-
loon back. Secure the Balloon by pull-
ing the Slipring over both the Valve 
and the Balloon Fixation Ring so that 
the Balloon Fixation Ring is no longer 
visible and the protruding end of the 
Balloon points backwards.

Align Valve Balloon to Valve

Valve Balloon ready to use

Fixing the Balloon with the Slipring

If needed, the extending collar can be 
trimmed away using a pair of scissors, 
making certain not to poke a hole into 
the Balloon.

11. AT TACHMENT TO THE 

EASY VALVE

 WITH  

BALLOON ADAPTER RESP. 

SOLID VALVE

Balloon Sets may be ordered 
from 

www.storz-bickel.com

.

The Liquid Pad is used to vaporize the 

extracts (aromatic oils) of the plants 
specified in the plant list. The stainless 
steel wire of the Liquid Pad serves as 
the carrier of the extract, comparable 
to the unvaporizable plant fibers in va-
porization plant material.

Caution! The extracts are 
usually concentrates; there-
fore, a very small dosage is 

sufficient. The vaporized concen-
trates may not be inhaled directly, but 
instead pumping them into the room 
air directly from the Filling Chamber 
without the Valve Balloon attached.

12.1. Preparation 

If the Liquid Pad is used, the Screens 
in the Filling Chamber are not re-
quired and should be removed. This 
applies to the Filling Chamber of the 

EASY VALVE

 as well as to the Filling 

Chamber of the 

SOLID VALVE

. In both 

cases the Liquid Pad is inserted in 
place of the lower Screen in the Fill-
ing Chamber. You will need the Filling 
Chamber Disc of the Filling Chamber 
Insert of the 

SOLID VALVE

 as this 

Valve cannot open without the Filling 

Chamber Disc. 

12. LIQUID PAD

Preparation to use the Liquid Pad

12.2. Application 

Turn the Filling Chamber upside down 

and use a pipette to drop the extract 
onto the center of the bottom of the 
Liquid Pad. The Liquid Pad can hold 
up to 10 drops. If you use an extract 
with unknown concentration, use 
maximum one drop and carefully in-
crease the amount until you achieve 
the correct dosage.

Applying drops with a pipette

Please note that oils become 
more liquid at high tempera-
tures. If you use too many 

drops, the extract could drip into the 
Hot Air Generator, which must be 
avoided.

42 

43

Summary of Contents for VOLCANO CLASSIC

Page 1: ...STORZ BICKEL GMBH CO KG INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions ...

Page 2: ...7 1 Installation 18 7 2 Heating Up 18 7 3 Temperature Setting 19 8 VOLCANO CLASSIC 20 8 1 Installation 20 8 2 Heating Up 20 8 3 Temperature Setting 20 Table of Contents Page 9 EASY VALVE 21 9 1 Application and Operation 21 9 2 Cleaning and Maintenance 24 9 3 Accessories 27 9 3 1 Filling Chamber Reducer 27 9 3 2 Dosing Capsules and Magazine 28 9 3 3 Disposable Lip Piece for Hygienic Use 30 10 SOLID...

Page 3: ...IC and VOLCANO DIGIT Liquid Pad Normal Screen Set Valve Balloon with Mouthpiece Filling Chamber with Cap Hot Air Outlet Ventilation Slots Temperature Regulator HEAT Rocker Switch Heater Air Filter Air Filter Cap AIR Rocker Switch Air Pump Heater Control Lamp Ventilation Slots AIR Button Air Pump HEAT Button Heater Plus Temperature Button Minus Temperature Button Set Temperature Display Actual Temp...

Page 4: ...mers should contact the following address Storz Bickel GmbH Co KG In Grubenäcker 5 9 78532 Tuttlingen Germany 2 SAFETY RECOMMENDATIONS 2 EXPLANATION OF SYMBOLS Explanation of Symbols Please follow these instructions carefully EU conformity symbol The manufacturer confirms with this symbol the compliance of the product with the applicable European directives and standards Caution Hot surfaces Never...

Page 5: ...ot Air Generator away from pets e g hamsters mice and other animals which could damage the insu lation of the mains adapter cord The Hot Air Generator may only be repaired by our Service Center In correctly performed repairs without 2 SAFETY RECOMMENDATIONS the use of original spare parts can prove dangerous to the user Danger to life when opening the Hot Air Generator as live components and conne...

Page 6: ...09 F Chamomile Matriarca chamomilla the blossoms 6 190 C 374 F Lavender Lavandula angustifolia the blossoms 1 130 C 266 F Lemon balm Melissa officinalis the leaves 2 142 C 288 F Sage Salvia officinalis the leaves 6 190 C 374 F Thyme Thymus vulgaris the herb 6 190 C 374 F The extracts aromatic oils of these plants can be vaporized at up to 130 C 266 F with the help of the Liquid Pad supplied with t...

Page 7: ...porization material is completely exhausted and must be replaced with new material However for the best aroma results it is advisable to replace the vaporiza tion material before this point It is important to watch the vapor den sity in the Valve Balloon A fine white vapor feels very comfortable when inhaled As the vapor gets denser the taste can get too strong A very high intensity density of the...

Page 8: ...oblems immediately switch off the Hot Air Generator and pull out the power plug from the socket Do not try to remedy the defect yourself Contact our Service Center directly Allow the device to cool down before it is packed away 6 4 Care and Maintenance Before any maintenance work is done the device has to be switched off and the power plug has to be unplugged from the power supply 6 VOLCANO DIGIT ...

Page 9: ...ct to technical changes Patents DE 198 03 376 DE 100 42 396 EP 0 933 093 EP 1 884 254 US 6 513 524 Manufacturer Storz Bickel GmbH Co KG In Grubenäcker 5 9 78532 Tuttlingen Germany 6 VOLCANO DIGIT AND CLASSIC HOT AIR GENERATORS 16 17 Problem Possible Cause Remedy No green light signal vis ible on the display of the VOLCANO no activation of the heater or pump possible Please make sure that the curre...

Page 10: ...s completed the temperature is con stantly maintained at the set value The luminous intensity of the yellow control lamp corresponds to the inten sity of the heating process For technical reasons the temperature in the Filling Chamber cannot be mea sured during vaporization During op eration the temperature is measured at the heat exchanger The display in dicates the reference values for the attac...

Page 11: ...e indicated values because of the heating and cool off process of the heat exchanger For example at level 6 from 185 C up to 195 C 365 F up to 383 F Select the desired temperature at the temperature regulator knob 8 3 Temperature Setting Vaporization Temperature Table 8 VOLCANO CLASSIC 9 EASY VALVE Fill Filling Chamber max 10mm min 1mm Remove Filling Chamber Cap 9 1 Application and Operation Turn ...

Page 12: ...ity in the Valve Balloon see Chapter 5 Factors influencing vaporization page 12 9 EASY VALVE Attach the Mouthpiece to the Valve and allow it to lock in place Caution Hot surface Never leave Filling Chamber on VOLCANO Detach Valve Balloon from Filling Chamber Never leave the Filling Chamber on top of the hot air outlet of the VOLCANO as long as the heater is on except when filling the Valve Balloon...

Page 13: ...quently inhaling the content 9 2 Cleaning and Maintenance EASY VALVE Balloon with Mouth piece The EASY VALVE Balloon and its Mouthpiece require no maintenance For hygienic reasons they should be replaced with a new Valve Balloon and Mouthpiece every two weeks To prevent any transfer of infectious germs the Valve Balloon and Mouth piece should be used only by one person and never shared by multiple...

Page 14: ...itable for vaporizing small amounts of plant material is the Filling Chamber Reducer which is available as an accessory along with the Dosing Capsules For vaporizing small amounts of aromatic oils the small Liquid Pad is to be used additionally The Filling Chamber Reducer is in serted instead of the Filling Chamber Cylinder see Chapters Disassem bling the Filling Chamber and As sembling the Fillin...

Page 15: ...e desired amount of Dosing Cap sules is filled and insert them into the Magazine The Magazine can hold up to 8 Dosing Capsules 9 EASY VALVE Attaching the Magazine Cap After filing the Dosing Capsules at tach the Magazine Cap and close it by turning it clockwise Filling the Dosing Capsules with aromatic Oils The Dosing Capsules with inserted Liquid Pad which are available as ac cessories can be fil...

Page 16: ...brand new and in a low germ but not fully sterile state The Lip Piece is equipped with a check valve This check valve reduces the danger of a potential contamination inside the Valve Balloon by preventing breathing into the Valve Balloon The Lip Piece is put on the Mouth piece slid until stop and is then ready for operation The Valve Balloon with Mouthpiece and the Lip Piece may be used by only on...

Page 17: ...es will start to vaporize 10 SOLID VALVE Fill Filling Chamber max 10 mm min 1 mm 10 1 Application and Operation The Balloon Material must be kept out of the reach of chil dren as it is a potential source of danger As an alternative to the VOL CANO Balloon only use heat resis tant food safe and odor free oven tubes and oven bags Filling the Filling Chamber Remove the entire Filling Chamber In sert ...

Page 18: ...er leave Filling Chamber on VOLCANO Attach the Mouthpiece to the Valve Balloon Make sure that both grippers are locked in place To inhale put the Mouthpiece to your lips and press them lightly against the Mouthpiece By doing so the Valve opens and the vapors can be inhaled from the Valve Balloon As soon as you remove the pressure from the Mouthpiece the Valve automatically closes Attach the Mouthp...

Page 19: ...he Balloon should be replaced whenever the Valve is cleaned For manual cleaning use rubbing alcohol with paper or cotton towels or dish washing liquid with warm water 10 SOLID VALVE Pull off Lip Piece The Mouthpiece Valve and Filling Chamber are easily disassembled within seconds for cleaning The com ponent parts of the Mouthpiece Valve and Filling Chamber may also be cleaned in a dishwasher The S...

Page 20: ...le in reverse order Remove the Valve Cap and Valve Ring Pull out the Valve Cylinder along with the Valve Spring of the Valve Housing In case of stiffness the component parts can be loosened by warming them up in warm water 10 SOLID VALVE Disassembling the Filling Cham ber Insert The Filling Chamber Insert can be easily removed from the Filling Cham ber The Filling Chamber Insert can be disassemble...

Page 21: ...n nearly every drug store and supermarket Do not use any other plastic bags or cling wraps The procedure to change a Balloon with a heatproof oven tube is described below Cut a piece of approx 50 60 cm 19 23 inch and tie it close at one end Cut a piece of approx 50 60 cm 19 23 inch 11 ATTACHMENT TO THE EASY VALVE WITH BALLOON ADAPTER RESP SOLID VALVE As the opening of the Balloon is much wider tha...

Page 22: ...e fore a very small dosage is sufficient The vaporized concen trates may not be inhaled directly but instead pumping them into the room air directly from the Filling Chamber without the Valve Balloon attached 12 1 Preparation If the Liquid Pad is used the Screens in the Filling Chamber are not re quired and should be removed This applies to the Filling Chamber of the EASY VALVE as well as to the F...

Page 23: ...normal use and will conform to Company s published specifications of the Products Notwithstanding the foregoing Company retains its right to deviate from its published specifi cations due to the latest innovations and improvements in function and design of the Products The forego ing warranty is subject to the proper storage transportation and use of the Products and does not include defects due t...

Page 24: ...r damages aris ing out of or in connection with this agreement shall in no event exceed the purchase price of the Products It is agreed and acknowledged that the provisions of this agreement allocate the risks between Company and Cus tomer that Company s pricing reflects this allocation of risk and but for this 14 WARRANTY LIABILITY REPAIR SERVICE 14 WARRANTY LIABILITY REPAIR SERVICE allocation an...

Page 25: ... GMBH CO KG In Grubenäcker 5 9 78532 Tuttlingen Germany STORZ BICKEL AMERICA INC 1078 60th St Suite A Oakland CA 94608 by STORZ BICKEL GmbH Co KG VAL 30 202 02 2017 sec_EN Subject to alterations All rights reserved ...

Reviews: