background image

If you choose to vary from these instructions 

your warranty will be impaired.

4

1. 

Join the three sheets 

C

 together with 2 fixings 

through the overlapping ribs, making sure the ends of 

the sheets are flush.

2. 

Cap the sheeting with the 2255mm “U” channels 

F

.

3. 

Fix the channels through the end ribs and  

every second rib in between.

4. 

Make sure you put at least one fixing per  

sheet up through the underside of the  

channel into the pan of the sheet.

1. 

Cap the sloping sheets 

E

 with the “U” channels  

G

.

2. 

Fix the channels through the end ribs and every 

second rib in between.

3. 

Make sure you put at least two fixings up  

through the underside of the channel  

into the pan of the sheet.

4. 

Repeat for other side wall with opposite slope.

1. 

Join the sheets 

D

 together, same as the back.

2. 

Cap the sheeting with the 2255mm “U” channels 

F

.

3. 

Fix the channels at every second rib but not the corners 

at this stage.

4. 

Place the short flange of the first “L” flashing 

K

 on 

top of the rib at one end. Make sure the ends are flush 

with the sheeting (diagram 1) and put one fixing in the 

centre to hold the “L” flashing. Fix the corners through 

the channels and one more between the corner and the 

centre fixing.

5. 

Perform the same at the other end.

6. 

Five fixings each “L” flashing.

Step 4:

Back wall

Step 5: 

Roof

Step 6: 

End walls

C

F

F

F

3 x 

1830 x 

780mm sheets. 

2 x 2255mm “U” channels.

D

D

E

F

F

F

G

K

K

K

3 x 

1980 x 

780mm sheets. 

2 x 2255mm “U” channels.
2 x 1980mm “L” flashings.

2 & 1/2 x sloping sheets per side. 
2 x 1785mm “U” channels.

You will need:

You will need:

You will need:

diagram 1

Channels 
will end 
15-20mm 
short at 
tops of end 
walls and 
10-15mm at 
bottoms.

E

E

G

G

Tip

Put extra fixings in 

for high wind areas, 

particularly on the 

underside.

C

Trim or fold corner

If you need advice, call us FREE on 0800 807 433  

or email us at [email protected]

Summary of Contents for Rite 4

Page 1: ...ting 1 plastic wrapped package Some parts have sharp edges and should be handled very carefully We recommend the use of protective gloves and footwear when assembling DO NOT attempt to erect this shed in windy weather All dimensions are approximate rite 4 Tools required Battery or electric drill 3 3mm 1 8th inch drill bit Screwdriver and riveter Tape measure Ladder Non slip gloves good shoes and g...

Page 2: ...f any are damaged or missing A B C D E F G J M H K N I L O Building your shed The basic task is to join the sheets together to form your panels and fit the channels to the top and bottom of these panels They will then join together to form your shed diagram 1 2 and 3 Pan Rib Important Remove the swarf drill filings from the panels as you assemble them All components are cut to length Do not cut an...

Page 3: ... channels 5 Turn the door over and fix the four corners through all the U channels and fit the door bracing from the bottom corner to the opposite centre to the top corner step 2 below Step 1 Door Assembly A A N O H H H J J J M You will need 1 Attach the first Z door jamb L to the 740mm sheet B on the rib with the narrow pan Attach the other Z door jamb to the 740mm sheet B 2 Lay the premade door ...

Page 4: ...top Put the padbolt on the door before erecting the panels It will stop the door swinging around diagram 1 Channels will come short of the ends of the sheeting by 10 15mm on all panels Fix through the top and bottom of the channels into the door jamb and spacer The door jamb goes on inside of the channel The higher side of the channel goes to the inside of the shed It is very important to include ...

Page 5: ...m U channels F 3 Fix the channels at every second rib but not the corners at this stage 4 Place the short flange of the first L flashing K on top of the rib at one end Make sure the ends are flush with the sheeting diagram 1 and put one fixing in the centre to hold the L flashing Fix the corners through the channels and one more between the corner and the centre fixing 5 Perform the same at the ot...

Page 6: ...x down through the top of the roof through the pan into the top channel of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through these fixings will end up on the outside of the walls Fit the door braces and install shed 7 Fit the door braces if not already done so Check that all filin...

Page 7: ...ooden floors Storite accessories We also offer a great range of accessories and extras to complement your new Storite Shed Please ask your nearest hardware store for further details Internal dimensions for the RITE 4 2235mm x 1785mm Peg the floor to the ground in a windy area Boxing Diagram shed recess 20mm 25mm 20mm 25mm 1 x 1 8mm Bolt set into concrete runner Internal Dimensions Approx 25mm rece...

Page 8: ...od photo of your finished shed with your details To help you we have listed some questions that you may like to answer There is no need to type every question only the question number and your answers are necessary 1 Where did you find out about our sheds 2 Where did you purchase your shed Was the sales person helpful 3 Were you happy with the delivery of your shed and your overall purchase experi...

Reviews: