![Stoll CMS ADF-3 Operating Instructions Manual Download Page 337](http://html1.mh-extra.com/html/stoll/cms-adf-3/cms-adf-3_operating-instructions-manual_1381795337.webp)
337
7
Repairing the knitting machine
7.3 Replacing parts
7.3.13
Replacing comb hook
1. Open the comb cover plate.
2. Call up the "Comb" window from the "Main menu".
3. Tap on the "Release brake (=X=)" key.
4. Push the comb take-down manually upwards (about 8 cm).
The cover rails of the comb take-down are located above the left
and right control unit.
5. Push the cover rails (1) to the side only until an open area results at the
repair point.
For this purpose, push the upper cover rails to the left until the repair
point.
Push the lower cover rails to the right until the repair point.
6. Remove the comb hook.
7. Insert the new comb hook.
8. Close the cover rails.
9. Close the comb cover plate.
10. Tap the "Reference run (=R=)" key.