![Stoll CMS ADF-3 Operating Instructions Manual Download Page 311](http://html1.mh-extra.com/html/stoll/cms-adf-3/cms-adf-3_operating-instructions-manual_1381795311.webp)
311
7
Repairing the knitting machine
7.3 Replacing parts
7.3.5
Remove needle bed or position it at an angle
This chapter contains instructions on:
Releasing needle bed
Removing needle bed
Positioning the needle bed at an angle
Screwing on the needle bed tight
Releasing needle bed
1. Transfer all stitches of the needle bed to be removed or positioned
vertically to the other needle bed.
2. When the carriage assembly is in the left reversing position, stop the
machine with the engaging rod. If a central lubrication is present, the
carriage must be in the left reversing position.
3. Tap the "Rel. drive brake" key in the "Manual interventions" window and
slide the carriage assembly to the left up to the stop.
4. Remove two screws (2) on each side of the machine.
Releasing needle bed
5. Releasing the rear needle bed for gauge E 10 - E 18:
Remove the screws (3). Push the connection (4) to the side. While
doing so, the impulse sensor rail is pushed to the side.
Link of the impulse sensor rail
Key
Function
Call up "Manual interventions" window
Key for calling up "Manual interventions" window
Summary of Contents for CMS ADF-3
Page 16: ...About this document 1 Warnings in the documentation 1 5 16...
Page 232: ...Adjusting knitting machine 4 Defining user profile 4 6 232...
Page 270: ...Setup Data 5 Setup1 Editing the setup file 5 5 270...
Page 296: ...Maintenance of the knitting machine 6 Lubricate knitting machine 6 3 296...
Page 410: ...Software Installation and basic settings 8 Diagnose Control 8 5 410...
Page 436: ...Machine Management Tools 10 Send email directly from the machine 10 4 436...
Page 444: ...Key word directory 11 444...