13
A.
Disassembly Of Front Door
1. Remove the front door by turning off the circular
knobs and then pulling the front door off the studs.
2. Remove the air bleed valve by unscrewing the knob
while holding the valve stem from behind. Remove
the compression spring and push air bleed valve
through the rear of the front door.
3. Remove the spigot through the bottom of the front
door (see Figure 13). Remove all O-rings from
spigots and air bleed valve.
B. Disassembly Of Auger
1. Remove the front auger support by pulling it
straight out of the freezer barrel.
Figure 13. Front Door Disassembly
Figure 15. Rear Seal Removal
2. Remove the plastic bearing from the front auger
support.
3. Remove the auger by pulling slowly and rotating
out of the freezer barrel. As the auger is
withdrawn, remove each plastic flight and spring
from the auger. Be careful not to scratch inside of
freezer barrel when removing flights or auger.
Remove the spring from each auger flight.
4.
Keep the rear of the auger tipped up once it is
clear of the freezer barrel.
5. Wipe spline lubricant off hex end of auger with a
paper towel. Remove the rear seal. Figure 15.
Figure 14. Auger Flight Removal
3.5 CLEANING DISASSEMBLED PARTS
Disassembled freezer parts require complete cleaning,
sanitizing and air drying before assembling. Local and
state health codes will dictate the procedure required.
Some state health codes require a four sink process (pre-
wash, wash, rinse, sanitize, air dry), while others require
a three sink process (without the pre-wash step). The
following procedures are a general guideline only. Consult
your local and state health codes for procedures required
in your location.
A.
To clean the freezer parts, disassemble all parts.
(Refer to section 3.4 for the disassembly of freezer
parts.)
B.
Place all front door and auger parts in clean 90° to
110°F (32°C to 43°C) water and wash thoroughly
(four sink procedure only).
C.
Place all parts in 90° to 110°F (32°C to 43°C) , mild
detergent water and wash thoroughly.
D.
Rinse all parts with clean 90° to 110°F (32°C to
43°C) water.
F.
Sanitize all freezer parts following procedures out
lined below.
3.6 SANITIZE FREEZER PARTS
A.
Use a sanitizer mixed according to manufacturer's
instructions to provide a 100 parts per million strength
solution. Mix sanitizer in quantities of no less than 2
gallons of 90° to 110°F (32°C to 43°C) water. Allow
the sanitizer to contact the surfaces to be sanitized
for 5 minutes. Any sanitizer must be used only in
accordance with the manufacturer's instructions.
B.
Place all parts in the sanitizing solution for 5 minutes,
then remove and let air dry completely before assem
bling in freezer.
Summary of Contents for U431 series
Page 1: ...Model U431 Serial 17978 and up OWNER S MANUAL Manual No 513568 4 May 2004 Rev 0 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 16: ...8 ...
Page 28: ...20 ...
Page 36: ...28 ...
Page 38: ...30 ...
Page 40: ...32 Figure 7 Mix Pump ...
Page 42: ...34 ...
Page 43: ...35 ...
Page 44: ...36 D I S C H AR G E S U C TI O N D I SC H AR G E S U C TI O N ...
Page 45: ...37 ...
Page 46: ...38 D I S C H AR G E SU C T I O N D I S C H AR G E S U C TI O N ...
Page 47: ...39 ...
Page 48: ...40 ...
Page 49: ...41 ...
Page 50: ...42 ...