10
H.
Dispense Rate Adjusters
The dispense rate adjuster limits the opening of the
spigot. To adjust product dispense rate, turn the
adjusting knob clockwise for slower flow and counter-
clockwise for faster flow.
I.
High Head Pressure Cut Out
If the head pressure exceeds 445 PSIG (28 bar) air
cooled and water cooled, the high head pressure
cutout will trip. The reset button can be accessed
from the side of the freezer.
J.
Low Mix Light
The low mix light will illuminate when the liquid level
in the mix container drops below two gallons.
K.
Front Door Safety Switch
The front door safety switch prevents the auger from
turning when the front door is removed. The switch
is open when the door is removed and closed when
the door is properly installed.