ID 442426.04
78
WE KEEP THINGS MOVING
Installation
6
Manual SD6
6.4
Communication modules
WARNING!
Danger of personal injury and material damage due to electric shock!
Always switch off all power supply voltage before working on the drive
controller! Note that the discharge time of the DC link capacitors is 5
minutes. You can only determine the absence of voltage after this time
period.
CAUTION!
Danger of property damage due to electrostatic discharge, among
others!
Provide suitable protective measures while handling open PCBs (e.g., ESD
clothing, environment free of dirt and grease).
Do not touch the contact surfaces.
WARNING!
Danger of personal injury and material damage due to electric shock!
Always switch off all power supply voltage before working on the drive
controller! Note that the discharge time of the DC link capacitors is up to 5
minutes. You can only determine the absence of voltage after this time
period.
CAUTION!
Danger of material damage due for example to electrostatic discharge!
Take suitable protective measures when handling open printed circuit
boards, for example clothing appropriate for ESD and an environment free
of dirt and grease.
Do not touch the contact surfaces.
You will need the EC6 or CA6 communication module to connect EtherCAT or
CANopen. EC6 is installed on the upper slot, the same as CA6. The installation
is identical for both communication modules.
You need:
•
A Torx screwdriver TX10.
•
The cover and screw included with the communication module.
Installation of the communication module
1. Loosen the fastening screw for the dummy cover on the top of the drive
controller.
2. Push the communication module into the drive controller on the guide
rails.
3. Push the module in so that the pin contacts are pushed into the female
connector strip.
4. Insert the tips of the cover included with the communication module into
the recess in the front at an angle.
5. Set the cover down on the drive controller so that the tips are resting under
the edge.
6. Fasten the cover with the two screws.