![Stober SD6 Series Manual Download Page 52](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243052.webp)
ID 442426.04
52
WE KEEP THINGS MOVING
Technical data
4
Manual SD6
4.10.1
Electrical Data
When designing and operating the Quick DC-Link, always observe the electrical data and the individual drive controller sizes and types.
The maximum DC link voltage is 750 V and the maximum permitted current is 200 A.
Size (voltage)
Type
I
1N,PU
[A]
I
2N,PU
[A] 4 kHz
I
2N,PU
[A] 8 kHz
Own capacity
[µF]
Charging
capacity
[µF]
Remaining
charging
capacity
[µF]
0 (1 x 230 V)
SD6A02
8.3
4
3
340
1620
1280
0 (3 x 400 V)
SD6A04
2.8
2.3
1.7
135
540
405
SD6A06
5.4
4.5
3.4
135
540
405
1 (3 x 400 V)
SD6A14
12
10
6
470
1405
935
SD6A16
19.2
16
10
560
1405
845
2 (3 x 400 V)
SD6A24
26.4
22
14
680
1405
725
SD6A26
38.4
32
20
1000
1405
405
3 (3 x 400 V)
SD6A34
45.3
44
30
430
5100
4670
SD6A36
76
70
50
900
5100
4200
SD6A38
76
85
60
900
5100
4200