![Stober SD6 Series Manual Download Page 239](http://html.mh-extra.com/html/stober/sd6-series/sd6-series_manual_1381243239.webp)
ID 442426.04
239
WE KEEP THINGS MOVING
Holding brake
11
Manual SD6
Display of the
Brakes are released
state.
The state is calculated from the brake release time
F04
and the activation of
the brake.
•
Element 0: Both brakes are released.
•
Element 1: Brake 1 is released.
•
Element 2: Brake 2 is released.
The parameter shows whether both brakes are released (after brake release
time and if applicable feedback through the brake module). The axis is ready
to move.
The parameter shows whether brake 1 is released (after brake release time
and if applicable feedback through the brake module). The axis is ready to
move.
11.7 B20 = V/f control mode (0 or 1)
When calculating t
close
and t
open
note section 11.2 Direct and indirect brake
Note also the following parameter descriptions for explanations of the function
of the specified parameters.
For control modes with torque specification only. Reference torque or reference
force currently required by the speed controller. The reference value for
consideration on the load side is
C09
, for consideration on the motor side
B18
.
In control modes ASM - U/f control, ASM - slip compensated and ASM -
sensorless vector control (
B20
), the brake is released so it will be released
when the motor-related velocity in
F02
is reached.
While the brake is released, an acceleration ramp is used which is calculated
from the total set time t
rel
and
F02
.
F09
brake is open
version 0
F09[0]
brake is open all utilized brakes
version 0
F09[1]
brake is open brake 1
version 0
E170
T-reference
version 0
F02
brake release speed
version 0