12
Appendix A
ID 441687.04
WE KEEP THINGS MOVING
Operation manual
42
DPV1 parameter job:
DPV1 parameter response:
Job header
•
Job reference:
Unique identification of the job/response pair for the master. The master
changes the job reference with each new job (e.g., Modulo 255). The slave
echoes the job reference in the response.
•
Job ID:
Two IDs are defined:
01
hex
Request/read parameter
02
hex
Change parameter
Telegram portion
Byte
Function
Info
Job header
0
Job reference
—
1
Job ID
—
2
Axis
—
3
Number of parameters
Fixed at 1
1. Parameter address
4
Attribut
—
5
Number of elements
Fixed at 1
6+7
Parameter number
—
8+9
Subindex
—
1
st
parameter value
(only for writing)
10
Format
—
11
Number of values
—
12 bis xx Values
—
Telegram portion
Byte
Function
Info
Response header
0
Job reference, echoed
—
1
Response ID
—
2
Axis, echoed
—
3
Number of parameters
Fixed at 1
1
st
parameter value
(only for writing)
4
Format
—
5
Number of values
—
6 bis xx
Values
—