5
Fundamentals of PROFIBUS
ID 441687.04
WE KEEP THINGS MOVING
Operation manual
20
5.2
Comparison of the PROFIBUS generations
This chapter summarizes the system characteristics applicable to drive
technology and the system differences:
Simultaneous operation of different inverter generations on one controller is
possible and easy (see figure). Only when the new acyclic services are used are
an inverter of the 5
th
generation of STÖBER inverters and an appropriate master
required. The use of these services does not interfere with the operation of the
other stations. When an older controller is used which does not support acyclic
services, operation with cyclic data (PZD and PKW) can be used.
Fig. 5-1 Schematic setup with different types of STÖBER inverters
PROFIBUS Standard
Properties
New Features
Meaning for FDS
5000 / MDS 5000
DP-V0
Cyclic data
communication (PZD
+ PKW)
—
Compatible with FDS
4000, ...
DP-V1
Zyklischer Daten-
austausch identisch
wie DP-V0
Acyclic se
alarm handling
New parameter
channel, available as
per PROFIDrive V3
MDS
5000
FDS
5000
SDS
5000
FDS
4000
FAS