Parameterize
ID 442289.06
32
Operation manual POSIDYN® SDS 5000
4
WE
KEEP
THINGS
MOVING
4.2
POSITool
The versatile interface between user and inverter is the POSITool software. It offers various possibilities for
the configuration of an inverter.
POSITool has an interface to represent programming. In the “free graphic programming” option, blocks are
linked and as a result a control sequence is realized.
STOBER also provides predefined applications for programming. This includes applications such as fast
reference value application and command positioning that are selected using a wizard.
POSITool provides the user with parameter lists for parameterization. Using the lists, the control sequence is
adapted to external conditions such as motor type, rotary encoder or bus systems. Limit values such as
maximum speed are also defined or display values such as the current speed are shown.
The program and parameters are transferred to the inverter via a serial interface (RS232). Afterwards it starts
processing. Here the user can observe the parameters via the serial connection. A scope function is available
to record the different values over time for use in further diagnostics.
More details about the use of POSITool can be found in the corresponding section of the POSITool operating
manual or programming manual (see section 1.3 Further documentation).
4.3
Operator panel
The operator panel is used for monitoring and changing parameter values. The operator panel consists of a
two-line display with 16 characters each and a keyboard. The keyboard has six keys for menu prompting and
two keys for local operation.
Tab. 4-1: Operator panel
Jumps back to operator level.
Resets parameter value.
Enter key: Opens the menu level, menu groups and the
parameters. Accepts a changed parameter value.
Selects a parameter in the menu group. During entry,
increases/decreases the parameter value (positive/negative).
Selects the menu group. During entry, changes the decade
(ones, tens, hundreds, etc.).
Activates/deactivates local mode (if programmed). In local
mode, deactivation also deletes the enable.
Enable for local mode I/O
(if programmed).
ESC
#
I/O