Diagnosis
O
peration
man
ual
POSIDYN
®
SDS
5000
18
7
ID 442
289
.06
WE KEEP THINGS MOVING
13
13.3.40 *ParaModul ERROR: ksb write error
13.3.41 *ConfigStartERROR parameters lost
Resolution
Level
Response
An error was detected when writing the
configuration in the configuration memory.
—
The configuration does not start.
Possible cause
Test
Measure
Acknowledgement
Faulty flash memory.
—
Replace the Paramodule.
—
The configuration is too
large for the configuration
memory.
•
Apply a suitable configuration via
POSITool and then save it (
A00
)
•
Replace the Paramodule.
Resolution
Level
Response
No parameter values are saved in the
Paramodule.
—
The configuration does not start.
Possible cause
Test
Measure
Acknowledgement
The control part was
switched off while
A00
was active.
—
•
Apply a suitable configuration via
POSITool and then save it (
A00
)
•
Replace the Paramodule.
—