![Stober POSIDYN SDS 5000 Operation Manual Download Page 141](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280141.webp)
Service
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
141
12
12.5.2.7
D96 Reference value generator
NOTICE
During this action, the motor shaft will move.
Make sure that the motor can turn freely during the action!
When you start the action, a square-shaped reference value is specified for the motor. You can parameterize
the reference value in
D93
to
D95
.
During activation, the enable must be inactive. If you have started the action in
D96.0
, you must activate the
enable.
The action can only be concluded by turning off the enable and quick stop! With a quick stop signal, the drive
is halted immediately.
During the action, the cycle time is set internally to 32 msec.
You can read the following result from the third element (
D96.2
):
1: aborted:
The action was aborted by turning off the enable.