Service
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
135
12
With the results
10
to
12
an error was determined while saving to Paramodule. If the results occur repeatedly,
the Paramodule should be replaced.
Result 14 means that saving was error-free. At the same time it is determined that the maximum number of
approx. 10,000 write cycles has almost been reached. The Paramodule should be replaced as soon as
possible (for the ID no. of the Paramodule, see the Accessories Chapter in the projecting manuals of the
inverter).
12.5.1.2
A37 Reset memorized values
The action
A37
resets memorized values
E33
to
E37
and
E41
. The action can be started in
A37.0
.
The action offers the following result (
A37.2
):
0:error free
.
12.5.2
Actions with enable
Actions which require that the motors be energized before these actions can be executed:
•
B40 Phase test
•
B41 Autotune motor
•
B42 Optimize current controller
•
B43 Winding test
•
D96 Reference value generator
•
B300 Brake test
, see chapter 7.7 Brake test
•
B301 Brake grinding
, see chapter 7.8 Brake grinding function
12.5.2.1
Execute
Please note that since parameter values be determined directly during these actions, you should perform the
action
A00 save values
afterwards so that the values are stored safe from loss due to power failure.
Information
Do not turn off the power of the control section (devices of the /L version: 24 V, devices of the /H
version: supply voltage) while the action is still being executed. Turning off the power while actions
are being executed will cause data to be lost. The display indicates the fault
*ConfigStartERROR
parameters lost" or *Paramodul ERROR - Read error
. In such cases, the application must be
transferred to the inverter again (POSITool or Paramodul).
Executing actions with enable
1. Change to the device state Ready for switch on.
2. Set the first element of the action to the value 1 (e.g.,
B40.0
= 1).
3. Enable the motor.
Element 1 indicates the progress of the action (e.g.,
B40.1
= 33 %).
4. Wait until element 1 indicates the value 100 % (e.g.,
B40.1
= 100 %).
5. Turn off the enable.
Element 2 indicates the result of the action (e.g.,
B40.2 = 0:error free
).
Summary of Contents for POSIDYN SDS 5000