![Stober POSIDYN SDS 5000 Operation Manual Download Page 131](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280131.webp)
Service
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
131
12
12.4.2
Replacing the firmware
WARNING!
Danger of personal injury or material damage due to unsecured loads. The firmware must be activated
after the download for a live firmware update. The control part and power stage of the inverter are
switched off during activation. Unsecured loads on the drive can therefore slip.
Secure the drive load before activation.
During a live firmware update the firmware is loaded to the firmware download memory without affecting
running operation. The firmware does not become active until it is accepted. The firmware stored in the
firmware download memory is kept as redundant firmware to increase safety.
Requirements:
•
The inverter controller is powered as a minimum (24 V at terminal X11). The power may only be switched
off during download if the software gives an appropriate instruction. You can also carry out the live
firmware update during ongoing operation.
•
You have connected a PC to the SDS 5000 or an IGB network.
•
You have configured at least one IGB network in POSITool.
You need:
•
POSITool version 5.4 or higher
Carrying out a live firmware update
1. In POSITool, open the
IGB: display connected devices
menu entry in the File menu.
You will see the following dialog screen that displays all devices connected to the PC:
Summary of Contents for POSIDYN SDS 5000
Page 194: ...Notes WE KEEP THINGS MOVING ...