Notes on safety
Operating manual ASP 5001
ID 442181.07
WE KEEP THINGS MOVING
7
2
2
Notes on safety
WARNING!
The inverter and its accessories pose dangers.
Read and observe the safety warnings in this section before you use the ASP 5001 in your application.
The ASP 5001 option does provide galvanic separation of the mains supply network. Dangerous voltages may
also be present at the motor terminals for the required safety function! The function is not a protection device
against
electric shock
according to DIN EN 60204-1.
•
Secure the system during maintenance or repair work by switching to zero-potential and using an
appropriate system protection!
•
Observe the regulations for emergency stop situations!
The accessory ensures that the rotary field is switched off.
•
Secure vertically moving axles against falling!
Note that controlling the
Safe Torque Off
safety function with OSSD signals can lead to unexpected machine
behavior. The inverter enable can not evaluate OSSD signals or tolerate them in the presetting.
•
Activate the OSSD tolerance of the interface by entering a delay corresponding to the OSSD signal in the
A43 Enable Switchoff Delay
parameter. Note that the OSSD signals are not evaluated but suppressed!
2.1
Component part of the product
As this documentation includes important information for the safe and efficient handling of the product, always
keep it in the immediate vicinity of the product until product disposal and ensure it can be accessed by
qualified personnel at any time.
Also pass on this documentation if the product is handed over or sold to a third party.