Concept
ID 442181.07
10
Operating manual ASP 5001
3
WE KEEP THINGS MOVING
3
Concept
WARNING!
Improper use poses a danger to life.
Safe technical integration of the 5th generation of STÖBER inverters is not permitted without the ASP
5001.
Using the STÖBER safety concept, configurations can be established up to and including
•
PL e in category 3 to DIN EN ISO 13948-1:2008-12 or
•
SIL 3 in HF1 to DIN EN 61800-5-2:2008-04.
The
Safe Torque Off
(STO) safety function is integrated in the inverter.
For a suitable external configuration, the
Safe Stop 1
(SS1) safety function to DIN EN 61800-5-2:2008-04 or
a category 1 stop to DIN EN 60204-1:2007-06 can be realized. In this way, STO constitutes a safe fallback
solution.
The devices from the 5th generation of STÖBER inverters meet the requirements for category 3 and HF1
configurations. Accordingly, the device has two switchoff distances that are independent of each other.
Current supply
for electronic
PDS(SR)- Power-Drive-System
(Safety Release)
control
part
Power pack
Motor
Frequency
V+
state
Encoder
STO channel A
STO channel A feedback
STO channel B
STO channel B feedback
Power supply
ASP 5001