Controller area network (bxCAN)
RM0090
1102/1731
DocID018909 Rev 11
CAN receive FIFO mailbox identifier register (CAN_RIxR) (x=0..1)
Address offsets: 0x1B0, 0x1C0
Reset value: 0xXXXX XXXX
All RX registers are write protected.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
STID[10:0]/EXID[28:18]
EXID[17:13]
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
EXID[12:0]
IDE
RTR
Res.
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Bits 31:21
STID[10:0]/EXID[28:18]
:
Standard identifier or extended identifier
The standard identifier or the MSBs of the extended identifier (depending on the IDE bit
value).
Bits 20:3
EXID[17:0]
:
Extended identifier
The LSBs of the extended identifier.
Bit 2
IDE
:
Identifier extension
This bit defines the identifier type of message in the mailbox.
0: Standard identifier.
1: Extended identifier.
Bit 1
RTR
:
Remote transmission request
0: Data frame
1: Remote frame
Bit 0 Reserved, must be kept at reset value.