background image

Model Number TAC-09CHSA/JAI5   

Reverse Cycle Inverter  

Split System Air Conditioner

INSTALLATION MANUAL

After Sales Support

Telephone: 

   

1300 886 649

Email: 

 [email protected]

Summary of Contents for TAC-09CHSA/JAI5

Page 1: ...Model Number TAC 09CHSA JAI5 Reverse Cycle Inverter Split System Air Conditioner INSTALLATION MANUAL After Sales Support Telephone 1300 886 649 Email info tempoaustralia com au ...

Page 2: ... 649 Email info tempoaustralia com au Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting the Installation Place 09 Installation 17 Information for the Installer 19 Other Useful Information ...

Page 3: ...h no charge for parts and labour The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure an...

Page 4: ...ing to buy a STIRLING product All products brought to you by STIRLING are manufactured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfaction are backed by our comprehensive warranty We hope you will enjoy using your purchase for many years to come ...

Page 5: ...em Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner Voltage Ensure that the mains voltage corresponds to that stamped on the rating plate Keep the switch or power plug clean Socket Check and ensure that the socket is suitable for the plug Fuse ratings The ratings of the fuse installed in the built in control unit are 3 15A 250V for ...

Page 6: ...oor unit as pictured below which are connected through copper pipes properly insulated and an electrical connecting cable The indoor unit is installed on a wall of the room to be air conditioned The outdoor unit is installed on the floor or on a wall on suitable brackets Technical data of the air conditioner are printed on the labels placed on the indoor and outdoor units The remote control has be...

Page 7: ...on Place PROTECT YOUR WARRANTY These installation instructions for the TAC 09CHSA JAI5 STIRLING Reverse Cycle Inverter Split System Air Conditioner are for use by an appropriately qualified installer Do not try to install the air conditioner on your own doing so will expose you to danger and void the warranty Contact a licensed installer Minimum clearances in mm Do not install the unit where it wi...

Page 8: ...e air discharge and operating sound level will not disturb neighbours Installation diagram Only persons and or companies qualified and experienced in the installation service and repair of refrigerant products should be permitted to do so The purchaser must ensure that the person and or company who is to install service or repair this air conditioner has qualifications and experience in refrigeran...

Page 9: ...ut the mounting plate in a perfectly level position vertically and horizontally Drill 32mm deep holes in the wall to fix the plate Insert the plastic anchors into the hole Fix the mounting plate by using the provided tapping screws as illustrated right Check that the mounting plate is correctly fixed Drilling a hole in the wall for the piping Decide where to drill the hole in the wall for the pipi...

Page 10: ...itable for outdoor use The plug must be accessible after the appliance has been installed so that it can be pulled out if necessary An efficient earth connection must be ensured If the power cable is damaged contact the after sales support line for advice on replacement NOTE The cable wires have been connected to the indoor unit s main PCB by the manufacturer according to the model without termina...

Page 11: ... the connections by using two wrenches working in opposite directions Water drainage from the indoor unit The condensed water drainage from the indoor unit is fundamental for the success of the installation Place the drain hose below the piping taking care not to create siphons The drain hose must slant downwards to aid drainage as illustrated right Do not bend the drain hose or leave it protrudin...

Page 12: ...connection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the bound pipe cables and drain pipe through the wall hole and mount the indoor unit onto the upper part of the mounting plate securely Press and push the lower part of the indoor unit tightly against th...

Page 13: ...me position for years without the screws becoming loose The unit must be installed following all relevant local regulations Water drainage from the outdoor unit Condensed water and ice formed in the outdoor unit while in heating mode can be drained away through a drain pipe Fasten the drain port in the 25mm hole placed in the part of the unit as illustrated on the right Connect the drain port and ...

Page 14: ...ning of the torque there may also be some leakage as the flange could be damaged The best way to tighten the connections is using a fixed wrench and a torque wrench as illustrated on page 11 Bleeding Air and humidity left inside the refrigerant circuit can cause compressor malfunction After having connected the indoor and outdoor units bleed the air and humidity from the refrigerant circuit by usi...

Page 15: ...lose the low pressure knob on the vacuum pump coupling Stop the vacuum pump Open the 2 way valve by turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device Turn the body of the 2 way and 3 way valves Disconnect the vacuum pump hose Replace and tighten all the caps on the valves ...

Page 16: ...piping is passed so that no air or water can enter Indoor unit test Does the ON OFF switch work properly Do the HEATING COOLING and FAN modes operate normally Do the TIMER ON and TIMER OFF functions operate properly Does each indicator light work properly Do the flaps for air flow direction operate normally Is the condensed water drained regularly Outdoor unit test Is there any abnormal noise or v...

Page 17: ...responding Stress using a 20cm wrench Part Tightening Torque N x m 6mm 1 4 15 20 Wrist strength Service port nut 7 9 9 52mm 3 8 31 35 Arm strength Protection caps 25 30 12mm 1 2 35 45 Arm strength 15 88mm 5 8 75 80 Arm strength Wiring diagram Please see the diagram instructions attached to the unit first Pipe details NOTE The cable wires have been connected to the main PCB of the indoor unit by th...

Page 18: ... 15A 125V Type of fuse used on the inverter outdoor unit controller for 9K is 61T with rating 15A 250V Model Capacity BTU hr 9k Sectional Area Power Supply Cable N 1 0mm2 AWG18 L 1 0mm2 AWG18 E 1 0mm2 AWG18 Connection Supply Cable N 1 0mm2 1 1 0mm2 2 0 75mm2 3 0 75mm2 0 75mm2 Inverter Type Model Capacity BTU hr 9k Sectional Area Power Supply Cable N 1 0mm2 1 5mm2 AWG18 AWG16 L 1 0mm2 1 5mm2 AWG18 ...

Page 19: ...t throw this appliance out with your household rubbish Electrical and electronic products contain substances that can have a detrimental effect on the environment and human health if disposed of inappropriately Observe any local regulations regarding the disposal of electrical consumer goods and dispose of it appropriately for recycling and recovery of the refrigerant Contact your local authoritie...

Page 20: ...After Sales Support Telephone 1300 886 649 Email info tempoaustralia com au ...

Reviews: