background image

State: 04.12.2020 p. 4

Mounting instructions for multiplay „ascendo 2 robinia“

Item-No. 51 7510 601

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.

7.  Align the towers as shown in diagram 1 and 3 on the foundations. Please 

take care that the connections of the wobble bridge (shown in diagram 4) 
are positioned face to face. Rotate the posts so, that there is a distance of < 
89 mm between the vertical stainless steel tube of the rail and the posts, to 
avoid traps.  
The distance between the posts and the bow of the slide should be  
> 230 mm. This can also also be achieved by rotating. 

Note: Do not screw the base plates onto the foundations yet!

8. 

Connect the wobble bridge (diagram 4d) as shown in diagram 5d at the flabs 
on the tower and fix it with the shackles included in the delivery.

9.  Connect the slide (diagram 4e) with the tower at the intended locatio accor-

ding to diagram 5b and fasten it with the screws and washers included in the 
delivery.

10. Place the climbing slant (diagram 4a) on the adpaters acc. to diagram 5c and 

fix it with the screws and pipe connectors which are included in the delivery. 

11.  Connect the climbing arc (diagram 4c) with the adapters and fasten it with the 

screws included in the delivery (diagram 5e).

12. 

Connect the fireman‘s pole (diagram 4b) acc. to diagram 5a on the adapters 
and fix it with the screws included in the delivery. 

13. Align the play equipment once more at the foundations. The wobble bridge 

should not be sagging. 

14. Drill holes into all foundations and screw the play equipment to the founda-

tions with the included heavy-duty dowels.                           

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo robinie

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Feuerwehrstange mit Bogen

1025-11-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo robinie

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Feuerwehrstange mit Bogen

1025-11-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Diagram 4a: attachment 

part „climbing slant“

Diagram 4b: attachment 

part „firemans pole“

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo robinie

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Feuerwehrstange mit Bogen

1025-11-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Diagram 4c: attachment part 

„climbing arc“

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo robinie

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Feuerwehrstange mit Bogen

1025-11-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

ascendo robinie

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Feuerwehrstange mit Bogen

1025-11-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Diagram 4d: attachment part 

„wobble bridge“

Diagram 4e: attachment part 

„slide“

Summary of Contents for ascendo 2 robinia

Page 1: ...51 7510 601 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved climbing arc tower wobble bridge slide climbing slant fireman s pole climbing wall rail post post shoe Diagram 1 Overall view of the play equipment ...

Page 2: ...ing period of 10 14 days depending on weather conditions and foundation size fill up and compress the holes between the foundation and the foundation hole with excavation 6 Clean the surface of the foundations and start with the installation of the play equipment Diagram 2 Top view Reinforcement plan Concrete foundation with reinforcement Foundation BSt 500S Stirrups Ø 8 mm lengthwise and cross Co...

Page 3: ... Larsheck 56271 Kleinmaischeid Deutschland Beton concrete gewachsenes Erdreich natural ground Legende stoßdämpfender Boden shock absorbing floor ES 09 09 20 stoßdämpfender Boden A Datum Änderung Rev 5392 450 400 1716 2921 A A 3656 1511 3650 4813 4031 1750 600 600 950 275 2871 1846 2904 1750 400 1100 500 1000 500 979 950 1750 561 2029 1996 711 A A 5410 6336 OHNE SCHRIFTLICHE ZUSTIMMUNG DER CONRADI ...

Page 4: ...enennung Gepr Blatt Datum Projekt Gez Zeichnungsnummer 1 20 A3 Name Feuerwehrstange mit Bogen 1025 11 00 Maßstab Simonis xx xx xx Gewerbegebiet Larsheck 56271 Kleinmaischeid Deutschland OHNE SCHRIFTLICHE ZUSTIMMUNG DER CONRADI KAISER GMBH DARF DIESE TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT NOCH DRITTEN MITGETEILT ODER ZUGÄNGLICH GEMACHT WERDEN NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER WENDET WE...

Page 5: ... 49 0 2689 92790 0 All rights and product modifications reserved Diagram 5c connection climbing slant J Diagram 5d connection wobble bridge Diagram 5a connection firemans pole Diagram 5b connection slide C C F H I J H I ascendo 1B Benennung Gepr Datum Projekt Gez Zeichnungsnummer Name Explosion 1026 00 00 Simonis xx xx xx Diagram 5e connection climbing arc ...

Page 6: ...es STAINLESS STEEL NOTE Play equipment which contain components made of stainless steel should not come with normal steel parts in contact Those steel parts may rub off and leave small steel particles in combination with moisture brown rust stains MAINTENANCE If such corrosion occur on stainless steel parts they are fine to remove with an abrasive 240 grit Please take care when transporting and se...

Page 7: ...opropyl alcohol or acetone However it should be noted that the dissolved soiling is not spread over the sur face again Do not use any chlorid or hydrochloric containing cleaning products nor scouring powder bleaching or silver polish cleaner Cleaning intervals depend on type and degree of soiling as well as on demands made on optical characteristics Therefore cleaning is advisable at intervals of ...