State: 30.06.2021 p. 2
Mounting instructions for multiplay „angulus 5“
Item-No. 51 7525 601
© stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid • Tel. +49 (0) 2689 92790-0 • All rights and product modifications reserved.
1. Select the location of the play equipment taking into account the required
minimum space (see diagram 2).
2. The impact area of a playground equipment with an enforced movement is
not allowed to overlap the impact area of other equipment.
According to DIN EN 1176-1, 4.2.8.5.2 shock-absorbing floors must be made
on the entire impact area of every equipment that cause forced movement.
3. Carry out excavation work for the foundations as shown in diagram 3.
After excavation compress the foundation floor.
Note:
The combination equipment is installed at play level. Pay attention to
items marked „play level” at play equipment!
4. Set up the concrete foundations according to diagram 3 with central, horizon-
tal reinforcement.
5. After a setting period of 10 – 14 days, depending on weather conditions and
foundation size, fill up and compress the holes between the foundation and
the foundation hole with excavation.
6. Clean the surface of the foundations and start with the installation of the play
equipment.
7. Fix the post shoes to the post using the screws included in the delivery, do
not tighten yet! Pay attention to the parallel alignment of the wooden surface
and the stainless steel plate (see diagram 6e).
8. Screw the two upper hexagons to the two lower hexagons at the intended
position (see diagram 4).
Diagram 2: Top view
R1500
R1500
1500
910
9000
5460
5500
8300
8500
4185
2000
500
500
8300
Fallschutzplatten
required safety slabs
Aufprallfläche
Impact area
mind. Fallschutzplatten
min. required safety slabs
OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE
TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER
ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER-
WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.
1
angulus5
Benennung
Gepr.
Blatt
Datum
Projekt
Gez.
Zeichnungsnummer
Rev
Änderung
Datum
1:50
A3
Name
Name
Draufsicht
1022-00-00
Maßstab
Behnke
28.02.17
A Mindestraum geändert
14.12.18 SI
SI
23.11.20
Aufprallfäche angepasst
B
Gewerbegebiet Larsheck
56271 Kleinmaischeid
Deutschland
Area of the minimum space =
Impact surface when using natural floors with a
shock-absorbing effect.
When using synthetic impact protection the impact area
shortens in the direction of the swing by 500 mm each.
The minimum space remains preserved in its entirety.
Reinforcement plan:
Concrete foundation with reinforcement
Foundation: BSt 500S
Stirrups Ø 8 mm lengthwise and cross
Concrete cover h´= 3 cm
Concrete quality class C20/25 – C25/30