Maintenance
5
Remaining ready for operation
7312_003-149_V2
5
4
6
– Remove the filter insert (4). Ensure that no
dirt can enter the intake opening (6).
– Wipe out the air filter housing using a damp
cloth.
– Check the filter insert (4) for contamination
or damage, and change it if necessary.
CAUTION
Risk of damage to components from contamination!
Damaged filter inserts must be changed to avoid
engine damage.
– Remove the cloth (6) from the intake
opening.
– Fit the air filter cover (2) from above at an
angle and install in the truck using a swivel
movement. Ensure that the sealing lip (5)
of the filter insert is seated correctly in the
housing.
– Allow the clamps (1) on the air filter housing
to engage.
– Close the bonnet.
7094_121-002
1
Draining water from the fuel filter
WARNING
Consumables are toxic.
Observe safety regulations when
handling Diesel fuel, see ⇒ Chap-
– Open the bonnet, see ⇒ Chapter "Opening
– Hold a suitable collection vessel under the
drainage screw (1).
– Open the drainage screw (1) on the filter
and drain the fuel (approx. 100 cm
3
) until
clean fuel is discharged.
– Manually retighten the drainage screw (1).
– Close the bonnet.
174749 EN - 03/2017
325
Summary of Contents for RX70-16
Page 1: ...Original instructions Diesel truck RX70 16 RX70 18 RX70 20 7311 7312 7313 174749 EN 03 2017 ...
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 35: ...2 Safety ...
Page 49: ...Safety 2 Residual risk 174749 EN 03 2017 37 ...
Page 67: ...3 Overviews ...
Page 78: ...3 Overviews Operating and display elements 66 174749 EN 03 2017 ...
Page 79: ...4 Operation ...
Page 310: ...4 Operation Shutdown 298 174749 EN 03 2017 ...
Page 311: ...5 Maintenance ...
Page 318: ...5 Maintenance General maintenance information 306 174749 EN 03 2017 ...
Page 322: ...5 Maintenance General maintenance information 310 174749 EN 03 2017 ...
Page 354: ...5 Maintenance Remaining ready for operation 342 174749 EN 03 2017 ...
Page 359: ...6 Technical data ...
Page 367: ...Technical data 6 Ergonomic dimensions 174749 EN 03 2017 355 ...
Page 378: ......
Page 379: ......
Page 380: ...STILL GmbH 174749 EN 03 2017 ...