Display messages
Error code table
The table gives an overview of possible
displays. In the "Comment" column you will
find information on how to proceed should any
of these messages be displayed.
Message text/
Error code
Comment
OVERHEATING
A5022
Traction motor(s) is/are too hot.
1st phase: regulation of acceleration and speed.
2nd phase: limitation of phase current in converter (emer-
gency driving function is retained).
The error automatically disappears as soon as the tempera-
ture is below the limit.
If the error occurs frequently, notify your authorised service
centre.
ACCELERATOR
A3002
A3003
A3004
A3005
A3006
A3007
A3505
Sensor fault, truck cannot be driven.
Notify your authorised service centre.
ACCELERATOR
A3008
Accelerator voltages (for dual pedal) do not match; truck
cannot be driven.
Notify your authorised service centre.
ACCELERATOR
A3811
Accelerator configuration is invalid; truck cannot be driven.
Notify your authorised service centre.
BRAKE SENSOR
A3016
A3017
Sensor fault; truck can only be driven at emergency mode
speed.
Notify your authorised service centre.
BRAKE SENSOR
A3035
Brake fluid level too low or switch defective; truck can only be
driven at the emergency mode speed.
Notify your authorised service centre.
CONFIGURATION
A2111
Parameterisation error or defective printed circuit board;
drive unit and hydraulic drive not functioning.
Notify your authorised service centre.
CONFIGURATION
A3801
Parameterisation error; drive unit and hydraulic drive not
functioning.
Notify your authorised service centre.
CONFIGURATION
A3812
Drive program parameters are outside the permitted range.
The drive program parameters are limited internally.
Notify your authorised service centre.
174749 EN - 03/2017
245
Summary of Contents for RX70-16
Page 1: ...Original instructions Diesel truck RX70 16 RX70 18 RX70 20 7311 7312 7313 174749 EN 03 2017 ...
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 35: ...2 Safety ...
Page 49: ...Safety 2 Residual risk 174749 EN 03 2017 37 ...
Page 67: ...3 Overviews ...
Page 78: ...3 Overviews Operating and display elements 66 174749 EN 03 2017 ...
Page 79: ...4 Operation ...
Page 310: ...4 Operation Shutdown 298 174749 EN 03 2017 ...
Page 311: ...5 Maintenance ...
Page 318: ...5 Maintenance General maintenance information 306 174749 EN 03 2017 ...
Page 322: ...5 Maintenance General maintenance information 310 174749 EN 03 2017 ...
Page 354: ...5 Maintenance Remaining ready for operation 342 174749 EN 03 2017 ...
Page 359: ...6 Technical data ...
Page 367: ...Technical data 6 Ergonomic dimensions 174749 EN 03 2017 355 ...
Page 378: ......
Page 379: ......
Page 380: ...STILL GmbH 174749 EN 03 2017 ...