Safety
3
Safety inspections
Safety inspections
Regular safety inspection of the truck
Safety inspection based on time and
extraordinary incidents
The operating company must ensure that the
truck is checked by a specialist at least once a
year or after particular incidents.
As part of this inspection, a complete check
of the technical condition of the truck must be
performed with regard to accident safety.
In addition, the truck must be thoroughly
checked for damage that could potentially
have been caused by improper use. A test
log must be created. The results from the
inspection must be retained until a further two
inspections have been carried out.
The inspection date is indicated by an adhe-
sive label on the truck.
– Arrange for the service centre to perform
periodic safety inspections on the truck.
– Observe guidelines for checks carried out
on the truck in accordance with FEM 4.004.
The operator is responsible for ensuring any
defects are remedied without delay.
– Contact your service centre.
NOTE
Observe the national regulations for your
country!
Insulation testing
The insulation of the truck must have sufficient
insulation resistance. For this reason, insula-
tion testing in accordance with DIN EN 1175
and DIN 43539, VDE 0117 and VDE 0510
must be conducted at least once a year as part
of the FEM testing.
The insulation testing results must be at least
the test values given in the following two
tables.
170525 EN - 10/2016
37
Summary of Contents for RX60-16
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 170525 EN 10 2016 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 58: ...3 Safety Emissions 46 170525 EN 10 2016 ...
Page 59: ...4 Overviews ...
Page 61: ...Overviews 4 General view of truck 170525 EN 10 2016 49 ...
Page 81: ...5 Operation ...
Page 344: ...5 Operation Cleaning 332 170525 EN 10 2016 ...
Page 345: ...6 Maintenance ...
Page 348: ...6 Maintenance General maintenance information 336 170525 EN 10 2016 ...
Page 352: ...6 Maintenance General maintenance information 340 170525 EN 10 2016 ...
Page 389: ...7 Technical data ...
Page 410: ......
Page 411: ......
Page 412: ...STILL GmbH 170525 EN 10 2016 ...