Maintenance
6
1000-hour maintenance / Annual maintenance
1000-hour maintenance / Annual maintenance
Other tasks
– Perform all maintenance work; see the
"Maintenance" chapter.
6210_110-001
1
2
2
Checking the cable terminals
– Check feed cable from pump motor (1) and
traction motor (2) for secure seating, status,
and insulation.
NOTE
Oxidised terminals and brittle cables lead to
voltage drops and thus to malfunctions.
– Remove oxidation residues and replace
brittle cables.
6311_003-010_V2
1
Checking the hydraulic oil level of the
hydraulic battery carrier
WARNING
Hydraulic oils are hazardous to your health and are
under pressure during operation.
– Note safety regulations for working with hydrau-
lic oils; see ⇒ Chapter "Hydraulic fluid", P. 3-40.
Checking the hydraulic oil level
– Park the truck securely; see ⇒ Chap-
ter "Parking the truck securely and switch-
– Remove the bottom plate.
– Unscrew sealing plugs (1) .
The oil level must lie between 65 and 70 mm
when measured from the base of the con-
tainer.
– If the oil level is below the required level,
top up the hydraulic oil via the filler neck
170525 EN - 10/2016
371
Summary of Contents for RX60-16
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 170525 EN 10 2016 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 58: ...3 Safety Emissions 46 170525 EN 10 2016 ...
Page 59: ...4 Overviews ...
Page 61: ...Overviews 4 General view of truck 170525 EN 10 2016 49 ...
Page 81: ...5 Operation ...
Page 344: ...5 Operation Cleaning 332 170525 EN 10 2016 ...
Page 345: ...6 Maintenance ...
Page 348: ...6 Maintenance General maintenance information 336 170525 EN 10 2016 ...
Page 352: ...6 Maintenance General maintenance information 340 170525 EN 10 2016 ...
Page 389: ...7 Technical data ...
Page 410: ......
Page 411: ......
Page 412: ...STILL GmbH 170525 EN 10 2016 ...