Cold store application
6210_900-002
Cold store application
The truck features cold store equipment
(variant), making it suitable for use in cold
stores.
It is equipped for two different types of applica-
tion and marked with the cold store symbol.
Cold store-compatible oils (for hydraulics
and gearbox) and greases (for moving parts,
gearing and chains) are used with the cold
store equipment.
Permissible use
Type of application 1:
• Constant deployment in temperature range
-5 °C, brief deployment down to -10 °C.
Type of application 2:
• Alternating between indoor use down to
-32 °C and for outdoor use +25 °C, briefly
up to +40 °C. For this application, cold
store-compatible hydraulic oil must be
used according to the maintenance data
table; see ⇒ Chapter "Maintenance data
Operation
CAUTION
Changing from a cold inside temperature to a warm
outside temperature may result in the formation
of condensation water. This water may freeze on
re-entering the cold store, blocking moving parts of
the truck.
It is essential that close attention is paid to the
duration of deployment in the different temperature
ranges for both types of application.
Before being used in the cold store, the truck must
be dry and warmed up.
The truck should not leave the cold store area for
more than 10 minutes. By adhering to this rule,
condensation water will not have time to form.
If the truck stays outside for longer than 10 minutes,
it must remain there at least until the condensation
water has drained off and the truck has dried off.
Depending on the weather, this will take at least 30
minutes.
55048011501 EN - 12/2015
211
Summary of Contents for RX50-10
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 24: ...1 Foreword Environmental considerations 12 55048011501 EN 12 2015 ...
Page 25: ...2 Introduction ...
Page 37: ...3 Safety ...
Page 60: ...3 Safety Emissions 48 55048011501 EN 12 2015 ...
Page 61: ...4 Overviews ...
Page 63: ...Overviews 4 General view of truck 55048011501 EN 12 2015 51 ...
Page 75: ...Overviews 4 Operating devices and display elements 55048011501 EN 12 2015 63 ...
Page 79: ...5 Operation ...
Page 305: ...6 Maintenance ...
Page 308: ...6 Maintenance General maintenance information 296 55048011501 EN 12 2015 ...
Page 312: ...6 Maintenance General maintenance information 300 55048011501 EN 12 2015 ...
Page 348: ...6 Maintenance 1000 hour maintenance Annual maintenance 336 55048011501 EN 12 2015 ...
Page 349: ...7 Technical data ...
Page 373: ......
Page 374: ...STILL GmbH 55048011501 EN 12 2015 ...