Maintenance
6
Maintenance every 1000 hours
Maintenance every 1000 hours
Work that must also be carried out
– Carry out maintenance work as neces-
sary, see ⇒ Chapter "Maintenance as re-
– Carry out 500-hour maintenance, see
⇒ Chapter "Maintenance every 500
Insulation resistance check (earth-
ing)
The insulation of industrial trucks should have
sufficient insulation resistance. Test the truck
and battery separately.
Testing the insulation resistance of the
electrical system
Have the insulation resistance of all active
electrical components checked in accordance
with DIN 57117 and DIN 43539, VDE 0117
and VDE 0520.
Measurement voltage > nominal voltage <
500 V. Insulation is considered correct when
it is measured in relation to the chassis and is
higher than 1000 ohm/V of nominal voltage.
Please contact your Service for this test.
50108043033 [EN]
137
Summary of Contents for KANVAN-05
Page 2: ......
Page 8: ...Table of contents g 7 Technical data Datasheet VDI 146 Wheels and tyres 149 VI 50108043033 EN ...
Page 9: ...1 Foreword ...
Page 18: ...1 Foreword Environmental considerations 10 50108043033 EN ...
Page 19: ...2 Introduction ...
Page 32: ...2 Introduction Residual risks 24 50108043033 EN ...
Page 33: ...3 Safety ...
Page 49: ...4 Overview ...
Page 65: ...5 Operation ...
Page 121: ...6 Maintenance ...
Page 139: ...Maintenance 6 Maintenance as required 1050_003 028 F5 F3 F1 F4 F8 50108043033 EN 131 ...
Page 140: ...6 Maintenance Maintenance as required 132 50108043033 EN ...
Page 152: ...6 Maintenance Maintenance every 5000 hours 144 50108043033 EN ...
Page 153: ...7 Technical data ...
Page 158: ...7 Technical data Wheels and tyres 150 50108043033 EN ...
Page 162: ......
Page 163: ......
Page 164: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 50108043033 EN ...