4
Testing and activities before daily use
CAUTION
Risk of component damage!
A deformed or damaged battery male connector
can cause overheating and related consequential
damage.
– Check the battery male connector for damage.
– If necessary, have the battery male connector
replaced by the authorised service centre.
To ensure that the truck is operated safely,
the visual inspections and function checking
must be carried out before daily use. The
components that must be checked and their
check points are listed in the following table.
If damage or other defects are identified on
the truck or the attachment (variant) during
the following inspections, the truck must not
be used until it has been properly repaired.
Damage or other defects must be reported
to the supervisor or the responsible fleet
manager immediately so that repairs by the
authorised service centre can be arranged.
Ensure that the truck is safe for operation each day before it is used:
Component
Course of action
Fork arms, general lifting accessories
Perform a visual inspection for deformation and wear
(for example, bent, broken, significant wear).
Check the condition and function of fuses (1) to
prevent lifting and shifting.
Roller tracks (2)
Make sure that there is a film of grease.
Load chains
Perform a visual inspection to ensure that the chains
are intact and have adequate and even tension.
Attachments (variant)
Ensure correct mounting in accordance with the
operating instructions of the manufacturer.
Perform a visual inspection to ensure the attach-
ments are intact and not leaking.
Perform checks to ensure the attachments are
working correctly.
Load measurement
Perform the load measurement once for testing
purposes.
Lift and tilt cylinders, tank, valve block,
hoses, pipes, connections
Perform a visual inspection for damage and leak-
ages.
Have damaged components replaced by the autho-
rised service centre.
Underside
Check the area under the truck for leaking consum-
ables.
50988078001 EN - 10/2018
75
Summary of Contents for FM-X EW Series
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 32: ...1 Foreword Environmental considerations 20 50988078001 EN 10 2018 ...
Page 33: ...2 Safety ...
Page 66: ...2 Safety Emissions 54 50988078001 EN 10 2018 ...
Page 67: ...3 Overviews ...
Page 85: ...4 Operation ...
Page 297: ...5 Maintenance ...
Page 304: ...5 Maintenance General maintenance information 292 50988078001 EN 10 2018 ...
Page 318: ...5 Maintenance Maintaining operational readiness 306 50988078001 EN 10 2018 ...
Page 319: ...6 Technical data ...
Page 350: ...6 Technical data Battery specifications for lithium ion batteries 338 50988078001 EN 10 2018 ...
Page 358: ......
Page 359: ......
Page 360: ...STILL GmbH 50988078001 EN 10 2018 ...