Operation
4
Handling the lead-acid battery
pressing the "stop button" on the battery
charger.
– Please refer to the operating instruc-
tions from the manufacturer of the battery
charger.
CAUTION
Risk of component damage!
If the plug for the battery charger is disconnected
from the battery male connector while the battery
charger is switched on, an arc is produced. This can
lead to erosion at the contacts, which considerably
shortens their service life.
– Switch off the battery charger before disconnec-
ting the charging cable.
– Switch off the battery charger.
– Disconnect the battery male connector from
the battery charger plug.
– Insert the battery male connector fully into
the plug connection on the truck.