Checking the condition of cables,
terminals and battery connector
–
Check that the cable insulation is undam-
aged and that there are no signs of over-
heating at the connections.
–
Check that the "+" and "-" output terminals
are not sulfated (presence of white salt).
–
Check the condition of the power outlet con-
tacts and the presence of the keying pin.
–
Check the condition of the locking tab on
the battery connector.
CAUTION
The points mentioned above can cause serious inci-
dents. In the event of a fault, please contact the Af-
ter-Sales Service.
Servicing the pump motor
Checking the electrical connections
–
Check the mounting, condition and insula-
tion of the pump motor cables (1).
–
Eliminate any traces of oxidation.
–
Replace faulty cables.
NOTE
Oxidised connections and faulty cables will re-
sult in a drop in voltage, leading to malfunc-
tions.
Service the on-board charger
It is necessary to check the on-board charger.
Proceed as follows:
–
Connect the cord to the 220 V mains.
Maintenance
5
Electrical equipment
107
1152 801 15 17 EN - 02/2021 - 14
Summary of Contents for EXU-H-18
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 20: ...Introduction 1 Disposing of components and batteries 10 1152 801 15 17 EN 02 2021 14 ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 40: ...Overviews 3 Markings 30 1152 801 15 17 EN 02 2021 14 ...
Page 41: ...4 Use ...
Page 94: ...Use 4 Handling the truck in specific situations 84 1152 801 15 17 EN 02 2021 14 ...
Page 95: ...5 Maintenance ...
Page 126: ...Maintenance 5 Commissioning and storage 116 1152 801 15 17 EN 02 2021 14 ...
Page 127: ...6 Technical specifications ...
Page 128: ...EXU H datasheet Technical specifications 6 EXU H datasheet 118 1152 801 15 17 EN 02 2021 14 ...
Page 140: ......
Page 141: ......