Electrical insulation testing
The truck's electrical insulation must have suf-
ficient insulation resistance. Insulation resist-
ance must be tested in accordance with EN
1175–1 and ISO 20898 at least once a year.
NOTE
The truck's electrical system and drive batter-
ies must be checked separately.
Measuring battery insulation resistance
NOTE
●
Test voltage > battery nominal voltage
●
The test voltage must not exceed 100 V or
triple the value of the nominal voltage
–
Measure insulation resistance using a suita-
ble meter.
The insulation resistance is sufficient when it
has a resistance of at least 50 Ohms multi-
plied by the nominal voltage of the truck cir-
cuit, between the parts under voltage and the
truck chassis.
Contact the After-Sales Service.
Measuring the insulation resistance of
the electrical system
NOTE
●
Test voltage > battery nominal voltage
●
The test voltage must not exceed 100 V or
triple the value of the nominal voltage
–
Measure insulation resistance using a suita-
ble meter.
The insulation resistance is sufficient when it
has a resistance of at least 1000 Ohms multi-
plied by the nominal voltage of the truck cir-
cuit, between the parts under voltage and the
truck chassis.
Contact the After-Sales Service.
Safety
2
Safety tests
31
5001 801 1555 EN - 12/2020
Summary of Contents for ECH 15
Page 1: ...Pallet truck ECH 15 Original instructions 0195 5001 801 1555 EN 12 2020 ...
Page 2: ......
Page 4: ......
Page 9: ...1 Introduction ...
Page 29: ...2 Safety ...
Page 46: ...Safety 2 EMC Electromagnetic compatibility 38 5001 801 1555 EN 12 2020 ...
Page 47: ...3 Views ...
Page 55: ...4 Operation ...
Page 68: ...Operation 4 Truck transport 60 5001 801 1555 EN 12 2020 ...
Page 69: ...5 Battery use and maintenance ...
Page 73: ...6 Maintenance ...
Page 84: ...Maintenance 6 Equipment scrapping and disposal method 76 5001 801 1555 EN 12 2020 ...
Page 85: ...7 Troubleshooting ...
Page 87: ...8 Lithium ion battery use and maintenance ...
Page 95: ...9 Technical data ...
Page 103: ......