FW 20 - TS 410, TS 420, TS 500i
English
8
N
Set the bracket bow to the full-
throttle position
N
Unscrew the hex nut (1)
N
Turn the sleeve (2) and set the
throttle cable as needed
N
Lock the sleeve (2) with the hex
nut (1)
Checking / adjusting the stop
Checking is only necessary if the carrier
has been replaced.
N
Distance (a) must be 1 to 2 mm –
otherwise, correct the position of the
stop (1) (arrows) and check the
throttle cable setting
N
Refit the two molding parts and
screw the knob on to the lever
Dismounting the cut-off machine
N
Raise (release) the tube locking
lever and raise the tube clear of the
machine
N
Lift out the cut-off machine
Trial cut
If the result of a trial cut is considerably
wider than the width of the abrasive
wheel segment
(approximately 1.5 times the segment
width), check that the abrasive wheel is
correctly fitted.
Transport
The star handle can be unscrewed and
the guide tube swung forwards for
compact transport (remove the water
tank, if fitted).