Alarm code
Description
Temperature too low
The temperature measured is below the minimum alarm limit calculated
Temperature too high
The temperature measured is higher than the maximum alarm limit calculated
Temp. sensor faulty
Value measured by temperature sensor < -50.0°C or > +100.0°C
Thermo-differential
Sensor x
The temperature difference between the last two sensor measurements is
greater than the maximum difference allowed or the sensor temperature is
higher than the absolute limit, see page 26.
Output already assigned
The output has been assigned to two or more controls.
Ventilation too low
1
The ventilation measured is below the minimum alarm limit calculated
Ventilation too high
1
The ventilation measured is higher than the maximum alarm limit calculated
Feed weigher (xx)
xx = alarm code from PFB feed weigher, for further information see the
manual with the PFB feed weigher.
Invalid feed weigher
Incompatible software version on the PFB feed weigher.
Update software PFB feed weigher.
Scale not found
The number of the scale does not occur.
1
2
At a flap control; first check if the flap is not in manual operation mode.
NOTE! If ALL feed dosing timers work with release contacts, the periods are allowed to overlap.
SYSTEM
SYSTEM
•
Device:
o
Type (158 = PL-9500).
o
Software version.
o
Software date.
•
WEC board:
o
Software version.
o
Operating system version.
o
Touch firmware version
DEVICE
Set language. Set the language for this manual to ENG (English). There is also a
possibility to change the name of the device.
Brightness:
on
Screen brightness if a key has been pressed.
off
Screen brightness after the “On time” has expired.
On-time
Time during which the screen is at its maximum brightness (On
percentage) after a key was last pressed.